A Brief Review of Troponin Testing for Clinicians - American College of Cardiology (2024)

Current American College of Cardiology and American Heart Association guidelines state that troponin is the preferred biomarker for diagnosing acute myocardial infarction (MI).1 Troponin T (TnT) and I molecules have amino acid sequences that are found only in cardiac tissue, making their assays highly specific for detecting cardiac damage.2 Over the years, as troponin assays have become more analytically sensitive and precise, clinicians have struggled with frequent "false positive" test results, defined as elevated troponin not representing MI. Now as newer troponin assays with even higher analytical sensitivity than previous assays are becoming available in the United States,3 many clinicians may be wondering if a higher analytical sensitivity test will create even more false positive test results. This concern, however, is unwarranted and is based on several misconceptions. In fact, newer troponin assays represent a significant improvement in laboratory testing, and if used properly will enhance clinicians' ability to rapidly diagnose patients with suspected acute coronary syndromes (ACS). These issues were addressed in our recent review article "Troponin Testing for Clinicians"4 and are briefly reviewed here.

The term high-sensitivity troponin is a source of confusion for clinicians. In the context of troponin testing, it is important to understand that high-sensitivity refers to analytical sensitivity and not clinical sensitivity. Clinicians use the terms sensitivity and specificity to describe the operating characteristics of a clinical test.5 They are taught that sensitivity and specificity vary depending on where investigators draw the line of demarcation between positive and negative test results (Figure 1, right panel). Generally, increasing the sensitivity of a test decreases the specificity. For troponin assays, however, high-sensitivity means that the assays have much lower limits of detection, enabling quantification of troponin at levels that were undetectable with earlier assays. Importantly, lowering the limits of detection for an assay may have no effect on the 99th percentile cut-point that determines the upper limit of the normal range. In fact, the 99th percentile cut-point for the newest high-sensitivity TnT assay is 0.014 ng/ml, which is very similar to the 0.01 ng/ml cut-point for the prior fourth generation TnT assay.3

The 99th percentile is another source of confusion. There are two common ways of determining a cut-point for a diagnostic test (Figure 1). The left panel shows a method using test measurements in a group of presumably normal subjects. With this method, the inner 95th percentile of a distribution of healthy subjects is used to define the normal range of a test. The right panel shows an alternative method using test measurements in groups of subjects in a clinical setting who are defined as having disease or no disease by another "gold standard" test. Generally, there is overlap between distributions of test results for subjects with and without disease. A line of demarcation is drawn at a point that maximizes the sensitivity and specificity of the test, often by using a receiver operating characteristic (ROC) curve method to help determine the optimal cut-point. For troponin testing, this ROC curve method was initially used to determine the cut-point using creatine kinase-MB to define MI. Investigators noted, however, that detectable troponin levels lower than the ROC curve-determined cut-point also portended a poor prognosis, as depicted by the gray area in Figure 2.6-9 Therefore, in 1999, an international panel of experts decided to use the former method of determining upper limit of normal, but they decided to use the 99th percentile rather than the 95th percentile as a cut-point.10 As troponin assays improved, the assays have become more precise and less subject to random or analytical variation, causing the shape of the distribution curve for a normal population to narrow, which has moved the 99th percentile to a lower cut-point (Figure 3).

Figure 1

Figure 2

Figure 3

Figure 4 shows a distribution of troponin results for a normal population using the fourth generation TnT assay on the left and the newer generation high-sensitivity assay on the right. With the fourth generation TnT assay, most people would have undetectable troponin levels, as shown by the dashed curve of a presumably normal distribution. With the newer assay, troponin would be detected at lower limits of detection, as shown by the solid portion of the blue curve in the right panel. The 99th percentile reported for the newer TnT assay is essentially the same as for the older assay, suggesting that the presumed shape of the distribution curves for the two assays is similar, as shown schematically in the figure.

Figure 4

With older troponin assays, troponin was undetectable below the 99th percentile cut-point, causing clinicians to consider any detectable troponin to be abnormal. With the newer assays, however, troponin will be detectable below the 99th percentile cut-point. Clinicians can no longer assume that any detectable troponin is abnormal, and they will need to compare each troponin result to the upper limit of normal for that assay, similar to the interpretation of other clinical laboratory tests. Clinicians will need to learn not to jump to conclusions about detectable troponin levels.

Most of the false positive test results that have frustrated clinicians are not the fault of the assay, and newer assays would not be expected to make this problem worse. The high false positive rate for troponin testing is largely due to indiscriminate ordering practices, which has created a problem known as spectrum bias. Troponin can be elevated in a variety of chronic conditions, such as renal failure or heart failure, or acute conditions, such as sepsis. When troponin is ordered in a narrowly defined population of patients who have a suspected ACS, excluding patients with renal disease or sepsis, the sensitivity of troponin is about 95%, and the specificity is about 80%.11 In Figure 5, the left panel shows a distribution of troponin test results for a hypothetical population for which the test is ordered in a narrow spectrum of patients that excludes renal failure and sepsis. When ordered indiscriminately in a broader spectrum of patients, however, the distribution curve of troponin test results widens for the patients without ACS. Because the cut-point remains fixed, the line of demarcation crosses the cumulative distribution curve at a lower point, indicating a markedly lower specificity or true negative rate. The right panel of Figure 4 shows a distribution of troponin test results for which the test was ordered indiscriminately in a broader spectrum of patients. As shown schematically, the cumulative probability curve (TNR) crosses the line of demarcation at a lower point, indicating a much lower clinical specificity. Thus, the deficiencies of troponin testing are largely a problem with clinical reasoning related to indiscriminate ordering practices and not a problem with analytical imprecision.

Figure 5

Newer high-sensitivity troponin assays have been available in Europe for years, and investigators there have proposed new ways of interpreting troponin test results.12 Some investigators have proposed using two cut-points: one at a high level to identify patients with ACS with a fairly high specificity and another cut-point at a very low level to identify patients without ACS with a fairly high sensitivity. Patients with troponin levels between the two cut-points would require further observation, and the high and low cut-points would enable early rule-in and rule-out strategies for many emergency department patients. This strategy is analogous to how we currently use electrocardiograms in the emergency department. Patients with ST elevation (analogous to a high cut-point) are sent for coronary intervention, while patients with normal or near-normal electrocardiograms (analogous to a low cut-point) are triaged to low-risk treatment strategies, and patients with in-between electrocardiographic findings are observed and receive additional testing.13

A single troponin test using a very low cut-point may be sufficient for ruling out an ACS in patients presenting with prolonged chest pain. For patients with chest pain of shorter duration, a single test at time zero may be too insensitive, and a second test 1 hour later has been proposed to improve the clinical sensitivity. If the second troponin level is higher than the first (even though both are below the 99th percentile cut-point), the delta could be used as a rapid and sensitive indicator of an ACS. Further investigation is needed to determine the best strategies for rapid diagnosis using the newer troponin assays.

In summary, the newer troponin assays are a marvel of modern medicine. Refinements in troponin assays now demand refinements in our clinical reasoning. Newer assays with improved analytical sensitivity will not likely alter the false positive rate. Improving the specificity of troponin testing (decreasing the false positive rate) can be addressed only by implementing better test-ordering protocols. Improved analytical sensitivity of the newer assays will enable more rapid and more effective rule-in and rule-out strategies. Now that the newer, more analytically sensitive troponin assays are available in the United States, clinicians will need to rethink how they order and interpret troponin tests. Greater understanding of the assay's operating characteristics could lead to more appropriate ordering practices and improved diagnostic accuracy for patients presenting with suspected acute MI.

References

  1. Amsterdam EA, Wenger NK, Brindis RG, et al. 2014 AHA/ACC Guideline for the Management of Patients with Non-ST-Elevation Acute Coronary Syndromes: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines. J Am Coll Cardiol 2014;64:e139-228.
  2. Jarolim P. High sensitivity cardiac troponin assays in the clinical laboratories. Clin Chem Lab Med 2015;53:635-52.
  3. Phend C. Next-Generation Troponin Test Cleared by FDA (Medpage Today website). 2017. Available at: https://www.medpagetoday.com/cardiology/myocardialinfarction/62620. Accessed 01/19/2017.
  4. Brush JE, Kaul S, Krumholz HM. Troponin Testing for Clinicians. J Am Coll Cardiol 2016;68:2365-75.
  5. Brush JE. The Science of the Art of Medicine: A Guide to Medical Reasoning. Manakin-Sabot, VA: Dementi Milestone Publishing, Inc.; 2015.
  6. Antman EM, Tanasijevic MJ, Thompson B, et al. Cardiac-specific troponin I levels to predict the risk of mortality in patients with acute coronary syndromes. N Eng J Med 1996;335:1342-9.
  7. Ohman EM, Armstrong PW, Christenson RH, et al. Cardiac troponin T levels for risk stratification in acute myocardial ischemia. GUSTO IIA Investigators. N Eng J Med 1996;335:1333-41.
  8. Lindahl B, Diderholm E, Lagerqvist B, et al. Mechanisms behind the prognostic value of troponin T in unstable coronary artery disease: a FRISC II substudy. J Am Coll Cardiol 2001;38:979-86.
  9. Morrow DA, Antman EM, Tanasijevic M, et al. Cardiac troponin I for stratification of early outcomes and the efficacy of enoxaparin in unstable angina: a TIMI-11B substudy. J Am Coll Cardiol 2000;36:1812-7.
  10. Alpert JS, Thygesen K, Antman E, Bassand JP. Myocardial infarction redefined--a consensus document of The Joint European Society of Cardiology/American College of Cardiology Committee for the redefinition of myocardial infarction. J Am Coll Cardiol 2000;36:959-69.
  11. Reichlin T, Hochholzer W, Bassetti S, et al. Early diagnosis of myocardial infarction with sensitive cardiac troponin assays. N Engl J Med 2009;361:858-67.
  12. Morrow DA. Clinician's Guide to Early Rule-Out Strategies With High-Sensitivity Cardiac Troponin. Circulation 2017;135:1612-16.
  13. Brush JE, Brand DA, Acampora D, Chalmers B, Wackers FJ. Use of the initial electrocardiogram to predict in-hospital complications of acute myocardial infarction. N Engl J Med 1985;312:1137-41.

Keywords: Troponin T, Troponin I, Acute Coronary Syndrome, Diagnostic Tests, Routine, Amino Acid Sequence, Chest Pain, Creatine Kinase, MB Form, Electrocardiography, Heart Failure, Myocardial Infarction, Renal Insufficiency, Biomarkers


< Back to Listings

A Brief Review of Troponin Testing for Clinicians - American College of Cardiology (2024)

FAQs

What are troponin tests used to assess quizlet? ›

a globular protein complex involved in muscle contraction. It occurs with tropomyosin in the thin filaments of muscle tissue. this test is used for: patients with chest pain to determine if the pain is caused by cardiac ischemia.

How high would an abnormal troponin level need to be to be considered for? ›

Levels that are higher than 0.04 ng/ml can indicate a recent heart attack or other injuries and conditions that affect the heart. Usually, doctors order troponin testing if they suspect that a person has had a recent heart attack.

What is an alarming troponin level? ›

For troponin concentrations 0.40 ng/mL and higher, the underlying cardiac injury is usually a myocardial infarction.

What is a 3 hour troponin rule out? ›

Patients with cardiac troponin concentrations ≥5 ng/L at presentation are retested at 3 hours. Myocardial infarction is ruled out at 3 hours if cardiac troponin concentrations are unchanged (Δ <3. ng/L) and remain ≤99th percentile.

What does troponin test measure? ›

A troponin test measures the levels of troponin T or troponin I proteins in the blood. These proteins are released when the heart muscle has been damaged, such as occurs with a heart attack. The more damage there is to the heart, the greater the amount of troponin T and I there will be in the blood.

What is the role of troponin quizlet? ›

Troponin forms the cross-bridges between actin and myosin. Troponin moves tropomyosin from actin so that the actin can bind to myosin.

Is elevated troponin always bad? ›

Higher than normal troponin levels don't always mean you've had a heart attack. They can be caused by unstable angina many other conditions that can damage the heart, including: Irregular heartbeat (arrhythmia), especially a heartbeat that's too fast. Heart failure.

What is the cutoff for elevated troponin I? ›

The manufacturer's upper reference level for troponin T is 14 ng/L. Based on the meta-analyses, cut-off values for troponin in patients with renal impairment with myocardial infarction was 42 ng/L for troponin I and 48 ng/L for troponin T. For patients on dialysis the troponin T cut-off is even higher at 239 ng/L.

What is the life expectancy of someone with high troponin levels? ›

Some 1782 (9%) patients died after a year, and a total of 2825 (14%) had died just over 2 years (809 days) later. Patients were nearly 4 times as likely to die if their cardiac troponin test result was high (45%) as those whose test results fell within the normal range (12%).

Can anxiety raise troponin? ›

However, in certain cases, troponin levels may be falsely elevated due to non-cardiac causes, including stress-induced myocardial stunning. Stress-induced myocardial stunning is a phenomenon characterized by reversible myocardial dysfunction in response to intense emotional or physical stress.

How to reduce troponin levels naturally? ›

The best way to keep your troponin level normal is to lower your risk of heart attack and other heart health problems that cause that damage. You can do that by leading a healthy lifestyle that includes eating a nutritious diet and exercising regularly. Your doctor can best tell you how to reduce risks to your heart.

What is the normal range for troponin I in the heart? ›

For example, the normal range for troponin I is between 0 and 0.04 ng/mL but for high-sensitivity cardiac troponin (hs-cTn) normal values are below 14ng/L. Other types of heart injury may cause a rise in troponin levels. These include: Atrial fibrillation.

How quickly does troponin return to normal? ›

Troponin is also useful even days after a heart attack because troponin I levels will remain high for at least five to seven days after a heart attack. Troponin T levels last even longer and will remain high for up to three weeks after a heart attack.

How much does a troponin test cost? ›

Other Heart & Cholesterol Tests/Packages That You Can Book with Redcliffe Labs
Tests/PackagesPrice in Rs.
Healthy Heart Package₹1199
High Sensitivity Troponin T Test₹1350
Healthy Heart Advance Package₹1599
Healthy Heart Premium Package₹3999
4 more rows

What is the peak for troponin levels? ›

High-sensitivity cardiac troponin T levels and clinical outcomes. Among all patients with STEMI, the median peak hs-cTnT was 3110 ng/L and mean was 5124 ng/L (range 20–57 875 ng/L) (reference range <14 ng/L).

What is the troponin T test used for? ›

A troponin test looks for certain types of the protein troponin, in your bloodstream. Those types of troponin only occur in heart muscle cells and only enter your blood because of heart muscle damage. That makes troponin invaluable in diagnosing heart attacks and other heart-related problems.

Why is troponin monitored? ›

A cardiac troponin test tells your physician whether or not you have had a heart attack. Doctors most often use these tests in the emergency room for a suspected heart attack. But they do have other uses, including: Heart attack long-term outcome.

How is troponin used as a cardiac marker? ›

Very high levels of troponin are a sign that a heart attack has occurred. Most patients who have had a heart attack have increased troponin levels within 6 hours. After 12 hours, almost everyone who has had a heart attack will have raised levels. Troponin levels may remain high for 1 to 2 weeks after a heart attack.

What cardiac enzymes are tested including troponin tests? ›

The results of a cardiac enzyme test can indicate if someone has experienced a heart attack. Doctors and scientists measure troponin in nanograms per milliliter (ng/mL). The higher the number of nanograms per milliliter within the blood, the greater the likelihood of a heart attack.

Top Articles
Latest Posts
Article information

Author: Rubie Ullrich

Last Updated:

Views: 6107

Rating: 4.1 / 5 (52 voted)

Reviews: 83% of readers found this page helpful

Author information

Name: Rubie Ullrich

Birthday: 1998-02-02

Address: 743 Stoltenberg Center, Genovevaville, NJ 59925-3119

Phone: +2202978377583

Job: Administration Engineer

Hobby: Surfing, Sailing, Listening to music, Web surfing, Kitesurfing, Geocaching, Backpacking

Introduction: My name is Rubie Ullrich, I am a enthusiastic, perfect, tender, vivacious, talented, famous, delightful person who loves writing and wants to share my knowledge and understanding with you.